Pneumatic And Hydraulic Equipment Page 733

Two Year Unconditional Warranty High Flow Quality Appearance Durable Finish Internal or External Pilot Supply Low Wattage Solenoid Operators Small Subbase Footprint Port and Operator Identification NUGGET 500 VALVES Fluids: Filtered lubricated or non-lubricated compressed air Pressure Range: Solenoid w/Internal pilot supply/, 20 to 150 psig Solenoid w/External pilot supply; 10" Hg (vacuum) to 150 psig Air Pilot operation; 10" Hg (vacuum) to 150 psig Temperature Range: Solenoid valves; -20F to 120F Air Pilot; -20F to 160F Average Flow Factor: 5.0 Cv Materials: Body-Aluminum, Spool-Anodized Aluminum Seals-Nitrile, Solenoid base-PPS plastic, Operator Housing-Zinc Minimum Pilot: Single Solenoid-40 psig (Operating Pressure) Double Solenoid, detent-30 psig Double Solenoid, spring center-40 psig Voltages: Standard: 120VAC 3.5 watts Optional: 24VAC 3.5 watts 240VAC 7.5 watts 12VDC 2.0 watts 24VDC 2.0 watts Duty: Continuous at 90 to 105% of rated voltage Coil Type: Class H. Molded with 3-pin plug-in connector Enclosure Classification: NEMA 4 per DIN 40050-IP65 Override: Manual, non-locking N O R G R E N norgren pneumatics JHF Catalog [ Volume 7 ] (314) 427-0600 800-444-0522 (FAX) 314-427-3502 www. j hf.com 733 Prices Subject to Change Without Notice John Henry Foster pneumatic and hydraulic equipment