Pneumatic And Hydraulic Equipment Page 647

AIR SYSTEM PRESSURE CONTROLLERS Storing air at high pressure is good working practice. The higher your stored pressure, the more volume you will have in your tank to meet peak system demands. But letting high pressure air into your system is the worst thing you can do. Intelliflow and PacE air system pressure controllers prevent high- pressure air from entering into your system. Overpressurizing tools and pneumatic components greatly reduces their life expectancy. In addition to protecting your equipment, these controllers will save considerable energy dollars through precise control of the demand side pressure. Reducing demand side pressure reduces the amount of air that escapes leaks in the plant air system and lowers the demand on your air compressor. The result is LOWER RUNNING COSTS. PacE PVR pressure regulator valve control Standard PID model Intelliflow High quality butterfly valve 3 valve bypass Minimum of 5:1 flow turndown Control valve defaults open on loss of control signal for safety Mounted PID controller NEMA 4 enclosure Modbus RTU capabilities Mounted filter/regulator 4" liquid filled pressure gauge Drain port PV model Intelliflow PVR pressure regulator valve control 3 valve bypass 4" liquid filled pressure gauge Drain port High Performance PID model Intelliflow Highest quality butterfly valve 5 year maintenance free valves 3 valve bypass Minimum of 10:1 flow turndown Control valve defaults open on loss of control signal for safety Mounted PID controller NEMA 4 enclosure Modbus RTU capabilities Mounted filter/regulator 4" liquid filled pressure gauge Drain port I N G E R S O L R A N D Model Connection SCFM Flow Max PSI Control Range Operating Temperature CCN % Full Span Series Control Number Part No. Size min max Inlet PSI Min. Max. Min. Max. Inlet Sensitivity Repeatability PacE Regulator PacE .5 38342119 1/2" NPT 0 40 232 7 144 -4F 176F 176F +/-0.2% of Full Span +/-0.5% PacE 38334314 1" NPT 0 250 232 7 144 PacE II 38041166 2" NPT 0 650 150 7 150 Intelliflow IR-NPT-PV-1.5 42544445 1.5" NPT 0 450 80-150 25 150 35F 115F 150F +/-1.5 psi +/-0.5% IR-NPT-PV-2.0 42544452 2" NPT 0 625 80-151 Connection Size Flow scfm Dimensions Model In/Out 110psig-in > 95 psig-out Length Width Height Weight CCN Series Control Number in min max in lb Number Intelliflow PID Microprocessor IX-02 2 207 835 39.25 15.00 33.87 180 23473192 IX-03 3 580 2,664 43.87 16.62 38.50 260 23473200 IX-04 4 1,077 4,868 58.50 18.06 44.25 440 23473218 IX-06 6 2,320 10,700 64.50 20.43 51.25 650 23473226 IX-08 8 4,144 19,200 70.68 70.68 53.06 860 23473234 IX-08CDN* 8 4,144 19,200 70.68 70.68 53.06 860 23485980 Maximum Pressure: 200 psig, Maximum Temperature: 150F, Maximum Pressure Turndown: 30%. Control air pressure to filter/regulator must be from 80 - 150 psig. Appropriate storage is critical for proper IntelliFlow operation. *IX-08CDN: Canadian Registration Number (CRN) is available on this 8" IntelliFlow only. IX-02 thru 06 have CRN standard. Ingersoll Rand JHF Catalog [ Volume 7 ] (314) 427-0600 800-444-0522 (FAX) 314-427-3502 www. j hf.com 647 Prices Subject to Change Without Notice John Henry Foster pneumatic and hydraulic equipment

Previous Page
Next Page