Pneumatic And Hydraulic Equipment Page 523

G A S T SIMPLEX Standard Pressure Setting Plumbing Tank Recovery of Connection Shipping Size ON/OFF 0 to Off Standard Female Weight Part. No. Price (Gal.) 0 10 30 50 70 90 psig Setting Setting Motor Voltage HP Length Height Width (NPT) lbs. ROA-P206T-AA $870.14 2 .60 .52 .40 .28 .19 .12 70/90 4:30 2:45 115-60-1 1/8 19 18 8 1/4 39 DOA-P706T-AA $887.35 2 1.00 .85 .50 .20 - - 30/50 1:30 0:55 115-60-1 1/8 18 15 8 1/4 39 1HAB-11T-M100X $976.95 2 1.25 1.10 .85 .65 .50 .40 70/90 2:45 0:55 115-60-1 1/6 18 17 8 1/4 49 1LAA-11T-M100X $940.09 2 1.5 1.35 1.1 .90 - - 30/50 0:50 0:20 115-60-1 1/6 18 17 8 1/4 49 2HAH-11T-M200X $996.22 2 1.65 1.55 1.30 1.15 1.00 .90 70/90 1:30 :24 115-60-1 1/4 18 18 8 1/4 56 3HEB-11T-M345X $1,322.22 12 2.40 2.20 1.85 1.50 1.30 1.20 70/90 6:45 2:00 115-60-1 1/3 26 21 14 1/4 93 4HCC-11T-M450X $1,609.59 20 3.50 3.30 2.80 2.40 2.10 1.80 70/90 7:00 1:55 115/230-60-1 1/2 33 27 16 1/4 118 5HCD-11TA-M550X $1,701.05 20 4.70 4.40 3.90 3.40 2.90 2.60 70/90 5:10 1:25 230-60-1 3/4 33 27 16 1/4 121 7HDD-11TC-M853 $3,644.96 30 9.00 8.40 7.25 6.50 5.75 5.25 70/90 4:00 1:00 200/230/460-60-3 2 38 29 17 3/8 155 DUPLEX 6HCA-15DTA-M616X $7,256.14 60 10.80 10.40 9.40 8.60 7.80 7.00 70/90 6:00 2:15 230-60-1 (2) 1 48 35 38 1/2 425 7HDD-69DTA-M750X $7,356.67 18.00 16.80 14.50 13.00 11.50 10.50 4:00 1:30 230/460-60-3 (2) 1-1/2 450 FEATURES Oilless operation Rugged construction; built for continuous duty INCLUDES ASME coded tank Pressure switch (DOA & ROA) Manual Drain ASME Safety valve Pressure gauge Globe valve Check valve CFM @ PSIG Pump Up Time In Minutes: Seconds (Approx.) DUPLEX CONTROL PANEL All electric components UL and CSA recognized. Panel mounted three position selector switch. Panel door mounted reset push-button for each magnetic starter. Motor Starters-Each motor is equipped with factory set thermal overloads. ALTERNATOR Automatically alternates which pump operates each cycle. The alternator is wired (control circuit) in such a way that if one pump cannot satisfy the demand alone, then the other pump will start and both will run until the demand is satisfied. MAGNETIC STARTER Supplied for each motor. This UL, CSA and IEC recognized component incorporates heavy duty contacts which complete (start) or open (stop) the circuit to the motor. TRANSFORMER The step down trans former supplies only the control circuit with 115 volts, the electric motor would operate at a higher voltage. The transformer is fused to protect the control components from a voltage surge which therwise could damage their operation. COMPRESSED AIR TANK SYSTEMS Gast JHF Catalog [ Volume 7 ] (314) 427-0600 800-444-0522 (FAX) 314-427-3502 www. j hf.com 523 Prices Subject to Change Without Notice John Henry Foster pneumatic and hydraulic equipment

Previous Page
Next Page